VERSION
INFORMATION     Change Description
----------------------------------------------------------------------
1.00            Initial Release.
                See the Scanner Information section for specific
                scanners and scanner settings that became available
                after the PhotoFinish manuals went to print.



----------------------------------------------------------------------
SCANNER INFORMATION
----------------------------------------------------------------------
To install or reconfigure a scanner for use with PhotoFinish, run
PFSETUP.EXE from Windows, and choose to install or reconfigure a
scanner. See your PhotoFinish Installation Guide for step-by-step
instructions on how to install your scanner.

Information about scanners included in the program since the
PhotoFinish Installation Guide went to print is included in your
PhotoFinish Setup Help and is also listed alphabetically below.

----------------------------------------------------------------------
***COMPLETE PC FLATBED SCANNER****

The Complete PC Flatbed scanner requires the CPFLAT.SYS driver provided by ZSoft and the CPCFSCAN.SYS driver provided by Complete PC.

CONFIG.SYS entry:
     device=CPCFSCAN.SYS
     device=CPFLAT.SYS

Port Addresses  Parameters
--------------------------
Use Defaults    Uses Port 3E0H
Port 3E0H       Scanner default
Port 3A0H       Adds /3A0 to CONFIG.SYS
Port 360H       Adds /360 to CONFIG.SYS
Port 320H       Adds /320 to CONFIG.SYS
Port 2E0H       Adds /2E0 to CONFIG.SYS
Port 2A0H       Adds /2A0 to CONFIG.SYS
Port 260H       Adds /260 to CONFIG.SYS
Port 220H       Adds /220 to CONFIG.SYS

Options         Parameters
--------------------------
Use Defaults    Uses DMA Channel 1
DMA Channel 1   Scanner default
DMA Channel 3   Adds /C3 to CONFIG.SYS.

Supported Settings
------------------
Brightness   3 settings
Contrast     Automatic only
Colors       B&W, 16 gray levels
Halftones    4 options
Resolutions  300x300, 200x200, 180x180, 150x150, 75x75, 50x50

----------------------------------------------------------------------
***CHINON N-207***

The Chinon N-207 scanner requires the CHINON.SYS driver provided
by ZSoft.

CONFIG.SYS entry:
     device=CHINON.SYS /A /P /U

Port Addresses   Parameters
-----------------------------
Use Defaults     Chinon.SYS accesses the 
                 port address for this scanner.

Options                    Parameters
-------------------------------------
Use Defaults               Uses Transmission Mode 3
Transmission
Mode 1 (high speed)        adds /C3 to CONFIG.SYS
Transmission
Mode 3 (line handshake)    Scanner default

Supported Settings
------------------
Brightness   3 settings
Contrast     Automatic only
Colors       B&W, 16 gray levels
Halftones    4 options
Resolutions  300x300, 200x200, 180x180, 150x150, 75x75, 50x50

----------------------------------------------------------------------
***GENIUS GS-4500***

The Genius GS-4500 scanner requires the GENIUS.EXE driver provided
by ZSoft.

CONFIG.SYS entry:
     device=GENIUS.EXE

Port Addresses  Parameters
--------------------------
Use Defaults    Uses Port 270H
Port 270H       Scanner default
Port 2E0H       Adds /P2E0 to CONFIG.SYS
Port 370H       Adds /P370 to CONFIG.SYS
Port 3E0H       Adds /P3E0 to CONFIG.SYS

Options                 Parameters
----------------------------------
Use Defaults            Uses DMA Channel 5, IRQ 10
DMA Channel 1, IRQ 2    Adds /D1 /I2 to CONFIG.SYS
DMA Channel 1, IRQ 5    Adds /D1 /I5 to CONFIG.SYS
DMA Channel 1, IRQ 10   Adds /D1 /I10 to CONFIG.SYS
DMA Channel 1, IRQ 11   Adds /D1 /I11 to CONFIG.SYS
DMA Channel 3, IRQ 2    Adds /D3 /I2 to CONFIG.SYS
DMA Channel 3, IRQ 5    Adds /D3 /I5 to CONFIG.SYS
DMA Channel 3, IRQ 10   Adds /D3 /I10 to CONFIG.SYS
DMA Channel 3, IRQ 11   Adds /D3 /I11 to CONFIG.SYS
DMA Channel 5, IRQ 2    Adds /D5 /I2 to CONFIG.SYS
DMA Channel 5, IRQ 5    Adds /D5 /I5 to CONFIG.SYS
DMA Channel 5, IRQ 10   Scanner default
DMA Channel 5, IRQ 11   Adds /D5 /I11 to CONFIG.SYS
DMA Channel 6, IRQ 2    Adds /D6 /I2 to CONFIG.SYS
DMA Channel 6, IRQ 5    Adds /D6 /I5 to CONFIG.SYS
DMA Channel 6, IRQ 10   Adds /D6 /I10 to CONFIG.SYS
DMA Channel 6, IRQ 11   Adds /D6 /I11 to CONFIG.SYS

Supported Settings
------------------
Brightness   255 settings
Contrast     255 settings
Colors       B&W
Halftones    1 option
Resolutions  300x300, 200x200, 100x100, 75x75, by multiples of 10

----------------------------------------------------------------------
***GENIUS GS-B105***

The Genius GS-B105 scanner requires the GENIUS.EXE driver provided
by ZSoft.

CONFIG.SYS entry:
     device=GENIUS.EXE

Port Addresses  Parameters
--------------------------
Use Defaults    Uses Port 270H
Port 270H       Scanner default
Port 2E0H       Adds /P2E0 to CONFIG.SYS
Port 370H       Adds /P370 to CONFIG.SYS
Port 3E0H       Adds /P3E0 to CONFIG.SYS

Options                 Parameters
----------------------------------
Use Defaults            Uses DMA Channel 5, IRQ 10
DMA Channel 1, IRQ 2    Adds /D1 /I2 to CONFIG.SYS
DMA Channel 1, IRQ 5    Adds /D1 /I5 to CONFIG.SYS
DMA Channel 1, IRQ 10   Adds /D1 /I10 to CONFIG.SYS
DMA Channel 1, IRQ 11   Adds /D1 /I11 to CONFIG.SYS
DMA Channel 3, IRQ 12   Adds /D3 /I2 to CONFIG.SYS
DMA Channel 3, IRQ 5    Adds /D3 /I5 to CONFIG.SYS
DMA Channel 3, IRQ 10   Adds /D3 /I10 to CONFIG.SYS
DMA Channel 3, IRQ 11   Adds /D3 /I11 to CONFIG.SYS
DMA Channel 5, IRQ 2    Adds /D5 /I2 to CONFIG.SYS
DMA Channel 5, IRQ 5    Adds /D5 /I5 to CONFIG.SYS
DMA Channel 5, IRQ 10   Scanner default
DMA Channel 5, IRQ 11   Adds /D5 /I11 to CONFIG.SYS
DMA Channel 6, IRQ 2    Adds /D6 /I2 to CONFIG.SYS
DMA Channel 6, IRQ 5    Adds /D6 /I5 to CONFIG.SYS
DMA Channel 6, IRQ 10   Adds /D6 /I10 to CONFIG.SYS
DMA Channel 6, IRQ 11   Adds /D6 /I11 to CONFIG.SYS

Supported Settings
------------------
Brightness   255 settings
Contrast     255 settings
Colors       B&W, Gray Scale
Halftones    1 option
Resolutions  B&W: 300x300, 200x200, 100x100, 75x75 by multiples of 10
             Gray Scale: 200x200

----------------------------------------------------------------------
***GENIUS GS-C105***

The Genius GS-C105 scanner requires the GENIUS.EXE driver provided
by ZSoft.

CONFIG.SYS entry:
     device=GENIUS.EXE

Port Addresses  Parameters
--------------------------
Use Defaults    Uses Port 270H
Port 270H       Scanner default
Port 2E0H       Adds /P2E0 to CONFIG.SYS
Port 370H       Adds /P370 to CONFIG.SYS
Port 3E0H       Adds /P3E0 to CONFIG.SYS

Options                 Parameters
----------------------------------
Use Defaults            Uses DMA Channel 5, IRQ 10
DMA Channel 1, IRQ 2    Adds /D1 /I2 to CONFIG.SYS
DMA Channel 1, IRQ 5    Adds /D1 /I5 to CONFIG.SYS
DMA Channel 1, IRQ 10   Adds /D1 /I10 to CONFIG.SYS
DMA Channel 1, IRQ 11   Adds /D1 /I11 to CONFIG.SYS
DMA Channel 3, IRQ 2    Adds /D3 /I2 to CONFIG.SYS
DMA Channel 3, IRQ 5    Adds /D3 /I5 to CONFIG.SYS
DMA Channel 3, IRQ 10   Adds /D3 /I10 to CONFIG.SYS
DMA Channel 3, IRQ 11   Adds /D3 /I11 to CONFIG.SYS
DMA Channel 5, IRQ 2    Adds /D5 /I2 to  CONFIG.SYS
DMA Channel 5, IRQ 5    Adds /D5 /I5 to CONFIG.SYS
DMA Channel 5, IRQ 10   Scanner default
DMA Channel 5, IRQ 11   Adds /D5 /I11 to CONFIG.SYS
DMA Channel 6, IRQ 2    Adds /D6 /I2 to CONFIG.SYS
DMA Channel 6, IRQ 5    Adds /D6 /I5 to CONFIG.SYS
DMA Channel 6, IRQ 10   Adds /D6 /I10 to CONFIG.SYS
DMA Channel 6, IRQ 11   Adds /D6 /I11 to CONFIG.SYS

Supported Settings
------------------
Brightness   255 settings
Contrast     255 settings
Colors       B&W, Gray Scale, 24 Bit Color
Halftones    1 option
Resolutions  B&W: 300x300, 200x200, 100x100, 75x75 by multiples of 10
             Gray Scale & 24 Bit Color: 200x200

----------------------------------------------------------------------
***MOUSE SYSTEMS PAGEBRUSH 32/COLOR***

The Mouse Systems PageBrush 32/Color scanner requires the MOUSYS.EXE driver provided by ZSoft.

CONFIG.SYS entry:
     device=MOUSYS.EXE

Port Addresses  Parameters
---------------------------
Use Defaults    Uses Port 270H
Port 270H       Scanner default
Port 2E0H       Adds /P2E0 to CONFIG.SYS
Port 370H       Adds /P370 to CONFIG.SYS
Port 3E0H       Adds /P3E0 to CONFIG.SYS

Options                 Parameters
----------------------------------
Use Defaults            Uses DMA Channel 5, IRQ 11
DMA Channel 1, IRQ 2    Adds /D1 /I2 to CONFIG.SYS
DMA Channel 1, IRQ 5    Adds /D1 /I5 to CONFIG.SYS
DMA Channel 1, IRQ 10   Adds /D1 /I10 to CONFIG.SYS
DMA Channel 1, IRQ 11   Adds /D1 /I11 to CONFIG.SYS
DMA Channel 3, IRQ 2    Adds /D3 /I2 to CONFIG.SYS
DMA Channel 3, IRQ 5    Adds /D3 /I5 to CONFIG.SYS
DMA Channel 3, IRQ 10   Adds /D3 /I10 to CONFIG.SYS
DMA Channel 3, IRQ 11   Adds /D3 /I11 to CONFIG.SYS
DMA Channel 5, IRQ 2    Adds /D5 /I2 to CONFIG.SYS
DMA Channel 5, IRQ 5    Adds /D5 /I5 to CONFIG.SYS
DMA Channel 5, IRQ 10   Scanner default
DMA Channel 5, IRQ 11   Adds /D5 /I11 to CONFIG.SYS
DMA Channel 6, IRQ 2    Adds /D6 /I2 to CONFIG.SYS
DMA Channel 6, IRQ 5    Adds /D6 /I5 to CONFIG.SYS
DMA Channel 6, IRQ 10   Adds /D6 /I10 to CONFIG.SYS
DMA Channel 6, IRQ 11   Adds /D6 /I11 to CONFIG.SYS

Supported Settings
------------------
Brightness   255 settings
Contrast     255 settings
Colors       B&W, Gray Scale, 24 Bit Color
Halftones    1 option
Resolutions  B&W: 300x300, 200x200, 100x100, 75x75 by multiples of 10
             Gray Scale & 24 Bit Color: 200x200
